Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can motor act as generator (OR) vice versa? explain how
does it do please post the answer technically

Answer Posted / ashish kumar rai

yes , ac motor can be used as alternator. only we have to
rotate shaft by any mechanical force.

Is This Answer Correct ?    35 Yes 25 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how could we know the size of cable by physical view?

1563


How to test REF relay testing for LV panel as per Kahramaa standard?

4877


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1820


surge tank, hrc fuse, earthing transformer, firm power objective type

1567


sometime battery charged and then automatically charged when rectifier ON conition, is there any chances please clarify the same.

1822


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2306


can u tell me the promotion from oiller to enginer

1878


What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.

2300


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

1072


Why do we need interlocking in a HT metering or Ring main unit switchgear?

1950


If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.

1041


why asa method ZPF method is more accurate than ASA method?

5749


How to calculate that clean water supply in one Day from 150 KLD STP?

1939


how to calculate the earth mat design in 132 kv substation yard ????

6164


Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.

2016