Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How do we check transformer losses and what are the ways to
minimise it.

Answer Posted / guest

transformer losses can be found by doing open circuit test
and short circuit test
open circuit test gives the core losses
short circuit test gives the copper losses
note in open circuit test the lv side is given supply and
in short circuit test the hv side is given supply

the iron losses can be reduced by providing laminations of
thinner dimension and using c.r.g.o sheet for laminations

the copper losses depend on the winding resistance which
increases due to heat can be reduced by providing
sufficient cooling to the winding.

Is This Answer Correct ?    36 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How dia computation perfomed in cold rolling mills .

3045


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1976


How to connect the chemical earthing and complete process tell me plz

1855


What's mean HVF & HAF in Vacuum Circuit Breaker?

5331


i need previous entrence exam papers of nhpc.

2833


what is the difference between RMS & TRUE RMS VOLTAGE

2929


what is LSR?

2186


what is the major difference between LIBBP & HIBBP.. which one is most preferable..

2967


In a large office how do we calculate required number of light fittings, assuming fittings are 4x18W or 2x36W fluorescent fitting ?

1865


why US countries maintains 110v and 60HZ

2181


A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03

2002


Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing

1901


Define load factor?

1100


Is there any question in the name of Static Switch in UPS??

1952


1. transformer design formula ? 2. how to calculate the primary turns and secondry turns ? 3. core types ? 4. how to find the primary current and secondry current ? 5. how to calculate the stacking factor ? 6. range of fulx density ?

11167