Why capacitor bank does not require in DG Set?
Answer Posted / viswanath
we controlled the powerfactor though with exciter.that why
we not using the capacitor bank
| Is This Answer Correct ? | 20 Yes | 16 No |
Post New Answer View All Answers
how to design the heater in temperature control unit to heat 50KL of water?
How to calculate the efficiency of Turbo Generator(Alternator) in general....?
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Define resonant frequency?
In MEP Services what are parts of STP and what are there function?
can u tell me the promotion from oiller to enginer
Haw to check conductivity of budbar
Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!
whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11
i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?
What do you understand by avr?
What is mean 2XWY
Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA
is there any lightning by passer is arranged in ship like buildings?