Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which starter is used for synchronous motor

Answer Posted / moti rgpv

1-:STAR -DELTA STARTOR
2-:COUPLING WITH INDUCTION MOTOR AND REMOVE THE MOTOR
AFTER GETING 80% TO 90% OF SYNCHRONOUS SPEED
3-:USING DAMPER BARS

Is This Answer Correct ?    48 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2149


why we use Test Terminal Block in 11 KV and 33 KV electrical panels.

1375


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.

1818


what is EIB lighting control system? what is the advantages of this system?

3904


what is meaning of bus riser

2574


Is RTCC panel needs any control supply.

2052


how we design a pannel to start 10HP motor with the help of star delta starter?

2221


in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?

1917


Why ground terminal is used in pot meter 10k ohms

1888


sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in

2030


how to decide choke rating for drive?

2320


What current flows in the transformer primary when its secondary is open?

1257


Why are the laminations insulated from each other?

1161


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

1958


we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

1679