Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if we convert kw into kva,which one formula use by us,pls
tell me?

Answer Posted / mohammed hussain a

Power in KVA = (1.732 * V in Volts * I in Amps)/1000*PF
For 3 Phase Supply



Power in KVA = (V in Volts * I in Amps)/1000*PF For 1
Phase Supply

or
KVA = KW/PF

Is This Answer Correct ?    34 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.

2173


I WANT BHEL PREVIOUS QUESTION

2422


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1931


i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?

2120


Why do we use copper cable for HT Supply and why not Aluminium?

2059


diff.between servo motor and ac motor

2109


why single phase to grd test in HV cable?why not 2 phase at a time?

2325


Draw the line diagram of diffretial relay connected to transformer?

2489


In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?

2207


why we use four type of phase angle difference between pimary & secondry winding of a transformer & where we use them?

2143


hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.

2779


Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???

2007


Explain about 3 phase motor fault current calculation with examples?

2994


THERMAL CAPACITANCE IS MEASURED IN..................................................

2199


What is the purpose of stablization resistor in high impedance bus bar protection

2066