Answer Posted / romesh roy nigam
Cogging - The rotar of squirral cage motar some times
refuse to start at all,particularly when the voltage is low
this when number of rotar teeth becomes equal to numbers of
stator teeth & due to magnatic locking between stator and
rotar teeth.
Crawling - The phenomenon when squirral cage motar some
times showing tendency to run stably at speed as low as one
seventh of its synchronus speed
| Is This Answer Correct ? | 16 Yes | 2 No |
Post New Answer View All Answers
What is difference between Over Current & Earth Fault protection?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
what is meant by tranformer impedance?
in dc suppy frequency is zero why? if dc frequency is zero how to exist dc transients and ac transients
What Normal(Tangent) towers and Tension(Cut-point) Towers?
HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?
Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet
How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?
what will be happen if earth point is being used for as a neutral point for raw power , and same will be used for ups earthing
How can we increase fuel-power ratio of any DG set?
hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)
Pl. brief about break-down maintenance of machine tool.
Transmission through a short line depends on
how to design step down 12 V, 1mA small transformer from 220 V AC? Because according to VI relation and power transfer it results bulky...