OUR METER READER TAKE READING OF INDUSTRIAL CONSUMER.THEY
ALWAYS ASK HOW TO INCREASE POWER FACTOR FROM 60% TO 99 % TO
AVOID PENALTY OF POWER FACTOR.
Answer Posted / zahid noor
Power Factor can be improved by installing Capacitors at
the end of consumer, why it is required, in order to
fulfill the loss during transmission of power to the end
of consumer, henceforth if consumer installs additional
capacitors for making this loss, penalty for PF below .95
can be avoided & for PF above .95 to unity , extra rebate
on monthly bills can be availed. Henceforth It is always
beneficial to achieve PF up to Unity.
In order to calculate the KVAR of capacitors to be
installed, it is required to know the details of consumer
regarding load, voltage level, type of load, switching
operations of load so as to finalize the capacity required
for achieving the same.
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
sir i ve applied for hindustan petroleum and power grid india ltd..and the exams on feb 22.can you pls send model papers and tell how to prepare for those.i need to get into any of these for sure.....
What is the effect of solar radiation on the design of an Isolated Phase Busduct?
Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp
Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?
how define the torque in ac drive. from electrical side in the drive friquency ,voltage and current three factor is there.
The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
WHAT IS THE WORKING PRINCIPLE OF A GENERATER.how is a GTG (Gas TURBANE Generater) working.plz explane
How to calculate the phase to phase clearness of HT /// LT bus bar?????
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%
what is ps impedance test
delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?
HOW MUCH CURRENT DOES SYNCHRONOUS MOTOR TAKES AT SYNCHRONOUS SPEED IN NO LOAD CONDITION ?
While testing a ZCT what parameters have to check or measure?
Can XLPE/SWB/PVC (P3) 7C X 2.5mm2 be replaced by Can XLPE/SWB/PVC (P2) 7C X 2.5mm2??? P3 vs P2