Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can w select the cable size for different rating load
& also waht r factors affecting the during selection of
cable?

Answer Posted / nilkanth

Cable size depend upon the full load current rating.Suppose
current rating is 86A then csble size is 35 SQMM.The
factores are the cunductor size and used cunductor

Is This Answer Correct ?    54 Yes 41 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why co incidence factor considered in transformer sizing?

1874


What is the difference between line drop and percentage line drop?

1573


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2254


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2219


How can I calculate the Mega watts required to run a plant having many electric motors and other electrical components.

2078


Did RMU have ct and pt ?

1363


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2349


what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1938


What are the disadvantages of hydropower?

1239


what is earth pit , how we can measured it, what earth rods reference

2623


in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?

1937


Why do we need interlocking in a HT metering or Ring main unit switchgear?

2032


What is difference between Harmonic and Non harmonic Capacitor Bank?

2930


describe the phenomena of vacuum interruption in C.B

1791


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1780