Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Do you know the faults occurs generally in motors and how
to rectify them?

Answer Posted / kannan

1. Over load tripping - Reset OL relay.
2. Ball bearing failure - To be identify by heavy noice and
offton tripping & Over heat - Change bearing.
3.Monthly once clean the body of the motor. cooling will be
better.
4. Winding problem. - Check by megger of multi meter.
Rewinding to be done.
5. Over load relay itself problem some times.

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

1059


what is the role of transistor in Circuit?

1194


prove that power consumed in 3 phase delta system is 3 times as compared to 3 phase star system

2292


why using transformer and thyristor switch in 3 phase apfc panel

2886


Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.

3803


Comment on the working principle of operation of a single-phase transformer.

1205


What is time response of the control system?

1100


dg earth connect only in the amf panel or not why

2096


What is the voltage gain or transfer function of amplifier?

1145


what is the difference between 2 way and 4 pole selector switch???

2460


how can we understand that where we have to use ac or dc coil for solenoid valve and why?what is the different between coil of ac and dc explain please.

1994


what is the effect of back reactive power on the generator ?

2210


What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)

1927


how we can calculate 2 phase welding transformer rating or total power?

1880


what are factors to be consider to design a HT & LT motor?

2327