why 4-20 mA signal is preferred over a 0-10V signal
Answer Posted / satishpatel
generally in a transister some amount of voltage is
required for turning it on. this voltage is the cutin
voltage. up to this voltage the exists a nonlinerity in its
charecteristics. beyond this cutin voltage the char. of
transister is linear. this nonlinear region lies between 0-
4ma,beyond 4ma it linear. this is why 4-20 ma range is used.
| Is This Answer Correct ? | 57 Yes | 95 No |
Post New Answer View All Answers
selection of the zener barrier for the hazardeous area zone 0
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
what are the values of fuel flow rate in various places in boiler.
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
Capacitance, resistance ( colour coding ), parallel & series circuits.
Give Detail information about plc,dcs,and scada system?
I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.
Why MUX JB's are using only Temperature Element in Fundation field bus?
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
centrifugal compressor interlock? Tell me the parameter at which compressor will trip
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
How to calibrate Magnetic flow Transmitter in Field
what is the different between deflection type measurement and null type measurement in RTD?