Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

At which conditions a synchronous motor acts as a
synchronous condenser?

Answer Posted / baswaraj

When Synchronous Motor's field winding is 'Over Excited' it
supplies the KVARs back to the the supply lines. This
property is similar to the Capacitor or Condenser.

Is This Answer Correct ?    54 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain (in simple ) - root mean square. whats its role in electrical fundamandal.where its used

2404


I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....

2099


Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?

1439


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2055


What is Antipumping Function & If we have C.T how we find the Ratio ?

2034


What happen in ups if phase reverse?

2301


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1932


define digital electronic

1993


How to calculat the ratio of HT\LT in energy meter

2720


comparision between ACB and VCB

2375


What is the formula to calculate the rating of a three phase miniature circuit breaker

2149


I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.

1415


How to select cable the size, what is the parameters use and what is the formulas use for this cable size calculation?

1924


HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION

2329


what are the application of over current relay?

5268