Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer rating in kva?

Answer Posted / m.bhuvaneswari

transformer copper loss is directly propotional to
current&iron loss is directly propotional to voltage. so
transformer rating is in kva.

Is This Answer Correct ?    26 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1876


Why we use auxillary relay ? what is function of differential relay, directional o/c relay?

2245


what is there inside an inverter and how it works?

1894


i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.

2159


what is the setting of locked rotor in HT motor ? (answer expecting in percentage)

2340


How to calculate per unit impedance of transformer?

2272


How REF protects transformer alone? explain with diagram.

1600


what is the necessity of under ground cables ??

2139


Operation carried out in thermal power stations?

1199


hi, could someone help me to find a control design for syncronising panel .

1777


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2712


Pl. share your experience about industrial-electronics repair of machine tool.

1944


What are the properties of a resistor?

1169


What is meant by derating factor?

1285


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1838