Answer Posted / raghuram
PLATE LOAD TEST IS TO FIND THE BEARING CAPACITY AND THE
SETTLEMENT OF THE FOUNDATION.
DESCRIPTION:: A TEST PLATE, SQUARE OR CIRCULAR IN SHAPE,
ARE USED. THE PLATE IS PLACED AT THE PROPOSED LEVEL OF THE
FOUNDATION AND IS SUBJECTED TO INCREMENTAL LOADING.
SETTLEMENT AT EACH INCREMENT OF THE LOADING IS MEASURED AND
A LOAD-SETTLEMENT CURVE IS PLOTTED. BEARING CAPACITY AND
THE SETTLEMENT OF THE FOUNDATION ARE DETERMINED FROM THE
LOAD-SETTLEMENT CURVES.
| Is This Answer Correct ? | 306 Yes | 26 No |
Post New Answer View All Answers
What is the withdrawal force of steel nails?
what is Brick crushing strength(PSI)?
silt%= silt volume/ silt+sand volume is this right?
For the calculation of bearing pressure below the footing, to know whether it is below the safe bearing pressure of the soil, the unit of RCC below ground level to be taken is 25 KN/m3 or (25-15)KN/m3, where 25 is the unit weight of RCC and 15 is the unit weight of soil and whether the weight of backfilling to be taken?
will fix foundation bolts at site with out template is there any procedure?
What is difference between engineering stress and true stress?
What is the meaning of soil reinforcement?
If u want ur Ans.Of any Question so mail me skatiyar011@yahoo.in
what is the anchorage length of reinforcement.
At one time what is the height of Lift for concreting for Bridge Piers Class B Loading and refer the code.
at which depth the construction of tunnel is economical from cost and engineering aspect.
What is the Unit weight of coarse sand (F.M- 2.20) ?????
Explain why concrete barriers have curved surface profiles?
In jack arch floor, the rise is kept?
Why Vitrified tile are getting pop up.