Answer Posted / prabhu gnanasekaran
RMU Stands for RING MAIN UNIT.
iF IT IS Power motor control center there will be 2 i/c
with a tie switch whereas if one fails the bus - coupler
gets closed then the routine loads are supplied this
arrangement is provided inorder to avoid the interruption
in power cut.
RMU also falls on the same concept but there will be 2 or
more incoming cable from different sub station but of same
voltage levels.
RMU comes into picture for uninterpted power supply for
industrial sectors also for other sectors.
RMU IS a big topic on protection and other basic things
which cannot be concluded in this.
it is crisp information that all
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
why steady state stability limit is greater than transient stability limit ? How it can be explained ?
How to calculate loses in transformer of 160 KVA ?
Define conversion efficiency of a power amplifier.
Difference between control junction box (cjb) and power junction box(pjb)?
Briefly describe means used by electricity suppliers to influence the flow of active and reactive power in power networks (one for each type)?
is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details
what is per unit calculation?looking for simple and strong explanation thk u
What is cathode ray oscilloscope (cro)?
why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
Transformer diagram mention each parts ?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?
Define branch?
Single line digram for 11 kV to distribution use go,la and do