WHAT IS BASICS TO SELECTION OF 11 kv Trasformer, send any
calculation sheet for selection of transformer
Answer Posted / prabhu gnanasekaran
11 KV transformer or anyother transformer the calculation
of the transformer is done only as per the loads connected
in it(Continious load,stand by load and Auxillary load). No
of motors connected to it,KW rating of the mator, Total
line current of all motors.
If it is 11 KV the your primary side of the transformer is
11 KV thats all. Due to this 11 KV the line current
calcultation will change in the factor of system voltage
level in Line current calculation of the motor.
| Is This Answer Correct ? | 8 Yes | 16 No |
Post New Answer View All Answers
How to design pavement quality concrete by using C.R.C.P Method
what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer
Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?
why sometime we get electrical shock while touching the ballon of dish tv connection ? which we should not get.
Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer
SIR, GIVE ME OPGW SAG CALCULATION FORMULA I AM DAE ELECTRICAL. THANKS
What is the formula to calculate the rating of a three phase air circuit breaker
is it necessary to earth the rmu before cutting off the transformer winding?if yes why?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.
WHAT IS THE DIFFERENE IN ACTION OF MCB,MCCB,RCCB
I am about to write exam in RRB bangalore for the post of section engineer.please provide me with previous exam questions
What is the high series capacitance winding on high voltage power transformer ?
What type of a DC motor would you use for a lift?
What are the three types of compensators?