Do you know how to joint the H.T and L.T Cables?
Answer Posted / vinothbhabu
hello dear,jointing the cable not by using transformer or
by fevicol,and its not a simple like paper r wood jointing
by fevicol..
by using the heat strinkable method cable jointing will be
done,the heat strinking method gives high insulation to the
cable at jointing end,it can be used for jointing ht panel
board at the termination end,the kit used for the heat
strinkable is heavely insulation material,the joint will be
done by heating material...
for jointing the LT to LT cable above 6
sqmm,10,16,35,50,70,90,120,150,185,240,300,400,sqmm cable
by jointing the FERRULE LUG between the cable joint by
using cripping tools and then insulation tape will be
rounded it heavely......
| Is This Answer Correct ? | 114 Yes | 17 No |
Post New Answer View All Answers
WHAT IS LOAD CELL
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.
Meaning of ingrace protection for motor.for ex IPXY
what is the meaning of impedance protected in instrument cooling fan
in my working site. momentary jerck in electrical supply ocurred frequently which cause of multiple losses in our electrical equipements. how can we protect our electrical machines and equipements in this situation.
What is the necessary condition for stability.
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
What would be the size of wire used for 2 Ton of window A.C?
what is the transmission loss for electrical supply? specifically a large shopping complex where the grid is half KM away, what will the % of transmission loss? is there any transmission loss for captive unit generation for above set? thanks
how does high earth to neutral voltage affect electronic equipment?
What is the Nyquist criterion regarding control systems?
On Which Pressure PRV is operated.
we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
any one can explain the stages of a knee point which is taken during ct magnetising curve.