What are the different condition monitoring techniques for a motor?
Answer
the following are the major condition monitring in motors.
running condition
1. load current, PF, RPM, voltage applied to th emotor
2. vibrations of the motor in all three directions, vertical, horizontal, axial
3. bearing vibrations( now days in one meter we can measure the both readings)
off condition
insulations resistance of the motor
winding resistance of the individual coil