PCB-00210: DISPLAY-1 only allowed with PIC G and PIC N variables "string"..

Answer / guest

Cause: A variable declared with DISPLAY-1 in the usage
clause without PIC G or PIC N in the picture clause was used
in a SQL statement.

Action: Replace DISPLAY-1 with DISPLAY or change the picture
clause to use PIC N or PIC G.