ORA-12505: TNS:listener does not currently know of SID given
in connect descriptor
Answer / guest
Cause: The listener received a request to establish a
connection to a database or other service. The connect
descriptor received by the listener specified a SID for an
instance (usually a database instance) that either has not
yet dynamically registered with the listener or has not been
statically configured for the listener. This may be a
temporary condition such as after the listener has started,
but before the database instance has registered with the
listener.
| Is This Answer Correct ? | 2 Yes | 0 No |
ORA-30184: argument type not compatible with a format code
DRG-12218: section group name missing
ORA-16040: standby destination archive log file is locked
ORA-25283: either agent's name or address needed for non-repudiation
ORA-00392: log string of thread string is being cleared, operation not allowed
TNS-00239: Connection Manager has been stopped
DRG-11218: malformed mail line, line string
PCC-02425: An indicator variable is not required with this attribute
SQL*Loader-00422: constant element count of number for column string is greater than maximum, number
ORA-25531: MTTR specified is too small: string
ORA-00825: cannot set db_block_buffers if sga_target set
AUD-00713: internal error while parsing audio data