what do you mean by MACO
Answers were Sorted based on User's Feedback
Answer / lava khandelwal
MACO = Maximum Allowable Carryover (MACO), its limit could
be establish as below:
TDDprevious x MBS
MACO = ------------------------------
SF x TDDnext
MACO Maximum Allowable Carryover: acceptable transferred
amount from
the investigated product ("previous")
Thanks
Lava Khandelwal
08650002470
| Is This Answer Correct ? | 8 Yes | 0 No |
Maximum Allowable Carryover (MACO)is the limit of previous product in next product during cleaning validation.
can be calculated by the formula-
TD x BS xSF
MACO = ----------------
LDD
where,
TD: single therapeutic dose of product A
BS : bach size of product B(minimum batch size)
SF: safety factor(1/1000) or 0.001
LDD : largest daily dose of product B
| Is This Answer Correct ? | 4 Yes | 0 No |
Please send me the model papers of Drug Inspector
What is limit of disintegration for Enteric coated tablets?
hi can anyone send me the model papers for drug inspector post,im frm ap....i completed my bpharm this year..pls help me,if u do i wl be very thankful to u...my email id- slpriyanka.r@gmail.com
Describe iso 9001 for pharmaceutical?
Hai,i had completed my M.pharmacy.i want the coaching centres for drug inspector exam at hyderabad,pls help me nd wen wil b the DI exam conducted in 2012 mostly,pls also forward the model papers.. pls reply me at vislawath.jyothi@gmail.com
What is the calibration of HPLC?
What is recovery factor?
when will tamilnadu govt announce the exam for DRUG INSPECTOR post?
1.mechanism of action -metformin 2.schedule y related to wat 3.define half life 4.wat is teratogenicity
paper for entrane exam for drug inspector
What will be in case stability sampleWhich have batch but distribute in three country.In tath case< we can put the sample for all country, whenevr all have same temp(Zone)
why should we not dispatch the reprocess material to export