Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why Multiload and Fastload does not supports SI,JI,RI and
TRIGGERS?

Answers were Sorted based on User's Feedback



Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / vinay

Above all concepts require communication between Multiple
Amps.
As per Fastload and Multiload doesnot provide any
communication b/w multiple Amps and they Operate
Independently.
As concept is violating as well as it takes time to
implement the above operation they are not allowing them.

Is This Answer Correct ?    12 Yes 1 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / yuvaevergreen

Vinay is correct.
SI -
USI - generally stored in subtable in a different amp other
than the amp having data row. Both the utilities do not
support.
NUSI - The subtable is stored in the same amp itself. Mload
supports it and Fastload not.

JI -
TD generally stores the rows of join index across the amps.
Both the utilities do not support.

RI and triggers -
These are multi amp operations and any operation involving
communication between two amps is not supported by these
two utilities.

Is This Answer Correct ?    11 Yes 0 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / dorai nagireddy

Vinay Sir simple answer is correct.Yuva your elaborated
answer is also correct.Thanks Vinay sir(Datawarehousing
Technologies faculty) and Yuva.

Is This Answer Correct ?    2 Yes 0 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / tdguy

USI,JI,RI and triggers involve multi amp communication.
Hence, both fload and mload dont these. But mload supports
NUSI alone as it is amp local.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Teradata Interview Questions

Hi friends This is suneel and i am new to teradata. In both situvations teradata administrator and teradata sql assitant 12.0 1)How to create database in teradata and under database how to create user. 2)How to create table under that user and giving privilizes to that user. Thanks alot.

1 Answers  


Which is more efficient group by or distinct to find duplicates?

0 Answers  


What is multi insert?

0 Answers  


Increasing no of amps will increase performance. Is this true?

5 Answers   Infosys,


Difference between Teradata V2R5 and Teradata V12 versions?

2 Answers   IBM,


Explain the term 'row' related to relational database management system?

0 Answers  


What are the scenarios in which full table scans occurs?

0 Answers  


Fast Load Script is failed and error tables are available then how do you restart?

3 Answers   TCS,


what are the roles and responsibilities of teradata DBA ?

1 Answers   TCS,


Explain teradata vs. Redshift?

0 Answers  


What is teradata? What are some primary characteristics of teradata?

0 Answers  


Suppose i have data like 2009/12/31 555555534 ' ' Generally last 2 records are wrong format it is going to error table but i don't want load error table if any wrong format in Date column Pass "NULL" how can we do it fast load

4 Answers  


Categories