Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why Multiload and Fastload does not supports SI,JI,RI and
TRIGGERS?

Answers were Sorted based on User's Feedback



Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / vinay

Above all concepts require communication between Multiple
Amps.
As per Fastload and Multiload doesnot provide any
communication b/w multiple Amps and they Operate
Independently.
As concept is violating as well as it takes time to
implement the above operation they are not allowing them.

Is This Answer Correct ?    12 Yes 1 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / yuvaevergreen

Vinay is correct.
SI -
USI - generally stored in subtable in a different amp other
than the amp having data row. Both the utilities do not
support.
NUSI - The subtable is stored in the same amp itself. Mload
supports it and Fastload not.

JI -
TD generally stores the rows of join index across the amps.
Both the utilities do not support.

RI and triggers -
These are multi amp operations and any operation involving
communication between two amps is not supported by these
two utilities.

Is This Answer Correct ?    11 Yes 0 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / dorai nagireddy

Vinay Sir simple answer is correct.Yuva your elaborated
answer is also correct.Thanks Vinay sir(Datawarehousing
Technologies faculty) and Yuva.

Is This Answer Correct ?    2 Yes 0 No

Why Multiload and Fastload does not supports SI,JI,RI and TRIGGERS?..

Answer / tdguy

USI,JI,RI and triggers involve multi amp communication.
Hence, both fload and mload dont these. But mload supports
NUSI alone as it is amp local.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Teradata Interview Questions

Backup Script was blocked then you are unable to archive the data. how do you analyze it and where do you identify ?

0 Answers  


What is the multi-insert?

0 Answers  


What do you mean by teradata intelliflex?

0 Answers  


what is identity columns in teradata

2 Answers   Wipro,


My table got locked during mload due to a failed job. What do I do to perform other operations on it?

0 Answers  


What are the different softwares used with their functions in teradata?

0 Answers  


Why FLOAD doesn't supports NUSI? Where as Mload supports NUSI. Please explain in this regard. Thanks in advance.

4 Answers   Teradata,


which option is used to restart the fastexport script ?

2 Answers   TCS,


What is upsert statement in teradata?

0 Answers  


Find 2 highest sal from each dept who have completed 5 year in org

0 Answers   Wipro,


How is MLOAD Client System restarted after execution?

0 Answers  


What are the uses of client software involved in teradata?

0 Answers  


Categories