Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

I wnat to practice more online type questions .so will you show them me to take a practice test?

VA Tech Wabag,

1 2857

what is span value and zero ? and how set ?

1644

Who to difference between analog in & analog out in dcs?

1756

need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate

1371

the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1752

What Is Pre- Commissioning Package +what is DCS & ESD Pre- Commissioning for Instruments Please explain your answer on practical ground base

1462

How to decrease opening & closing time of on/off valve?

UPL,

1551

Difference between guide wave radar & non guide wave radar ?

UPL,

1 2365

Why flow/pressure transmitter before control valve?

UPL,

1617

Relation in MMWC to Flow rate

1 2371

is motorized valve closed when power shutoff?

Unilever,

1795

What is three element in drum level?

1456

What is 3 element control system

1541

A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

1406

A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1462


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Describe the function of Accumulator into the Pump

2004


Hi, Is there any smart plant instrumentation design training institute in Bangalore?

1711


Why not come out analog output in ABB EL3020 when display show correct value

1942


what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?

2246


What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller

2413


how to check earthing,what is minum ohms for proper earthing

1999


what is The specifications for oriface instalation

2201


Explain the working of an enraf level gauge.

1147


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1951


The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?

2332


sir, give me placement papers and interview quistion of birla group company of copper.

2900


what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?

1688


Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.

1977


In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.

2022


Displace type LT to be calibrated in workshop, wt. 40, dia- 60 mm, density- 0.8kg/cm3.

1926