Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

So I'm a first year apprentice and I'm having a tough time with knowing the difference between AI, AO, DI, DO. I'm having a hard time understanding what devices are which and why. Can someone explain this to me?

2 2871

How to calibrate the flow transmitter

1608

i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1463

We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

OPaL,

1658

What is 3 selection available when configure the burnout protection for controller

EI Electrotechnical Institute,

2703

Why trim span ? How?

1588

Any body have know try work calculation ???

1428

What is cut off relay? And why use in PLC and DCS?

1373

Please why do we use 4-20ma in instrumentation engineering

1 1951

If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?

1451

How is work 5/2 sov?

1873

open tank and close tank leavel transmiter about range and calibration

1534

Can we use mov instead of esdv Explain the reason

KOC,

1 2379

What are the questions asked in fresher instrumentation candidates

Polmon,

1459

How we calculate orifice plat size???

1529


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

What is modbus?

1199


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10844


I need to know steps to Calibration Valve Guard......

1485


how many maximum enter 2mm Dia solid cylindrical pipe into 8mm Dia hollow cylindrical pipe. give answer with calculation.

2039


what is different between 2,3&4 wire rtd and how much maximum distance using plc to field.

2775


What is the difference between conductive lined pipe and conductive unlined pipe? Why do we see that?

3187


why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .

2880


is motorized valve closed when power shutoff?

1730


the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

2076


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7920


how many type conductivity sensor ?

2048


what is IEC code in cables & how to selecting cables?

1815


Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com

2285


Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?

1762


Why do we floating DC in DC system.

2896