how many types of viberation transmitter and how to calibrate and where use of vibration transmitter
2138Dear sir I am MD.zafar eqbal. I have taken this id from allinterwiev .com I have qustion if you dont mind. 1.what is the maximum operating temprature in instrumentation. 2. I want know about viberation i mean wahat types of sensor used in viberation And what types of trabsmitter used.and hiw to control it and wher is used of viberation transmitter and finally how to control it and what types of fault come. Sorry for disturbing you. I know you have no reason for help me. Because you dont know about me.but i request you please help me these question are very usefull for my feauture.plz sir Thanking you. Sent from Yahoo! Mail on Android
4 6333Post New Instrumentation Questions
Why mmwc unit is used?
why fuse block is not used for AI signal?
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?
what is Best Among SINK Or SOURCE Type Design In Digital Signal, Either Iput Or Output? WHY?Can any one..
A length of steel pipe is used to carry sea water to a desalination plant. An adequate corrosion allowance must be specified and indicated in the piping specification, which affects the _________________________ of the pipe
How addressable fire systems work? Pl. send details with architect.(Loop), also send details regarding Gas system. Pl. help me.Thanks
Why not come out analog output in ABB EL3020 when display show correct value
what is the input to be given in digital flow meter during the the calibration time?
what is the imbustion control loop
What is 3 selection available when configure the burnout protection for controller
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
How many interlocks at turbine? Plz explain briefly
How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
what is difference between fork type and capacitance type level switch. where it is using