Can any one advised me how we can measure the losses in a 11kV/415v power transformer? We have no access to the incoming mains into the primary of the transformer. Can one derive something useful by measuring temperature rise in the transformer?
1 3451What should be the neutral and body grounding sysytem for grid (132 KV) parallel generators (440 volts)?
1 5171In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for this?
6 14172In a thermal power plant ID Fans running with full load but boiler load is only 80 % give reason ?
9 19960Post New Power Plant Engineering Questions
Why superheated are started before I'd and rd fan?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
why airtel use + 24 volts and other operators use -48 volt
can dp type level transmitter work in under vaccum condition
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
operation
what is restricted earth fault explain in details
How We Calibrate the vaccum transmitter?
what is the basic use of power plant in equipment
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
why do you consider yourself a suitable candidate for this position
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
what is the trip circuit supervision in an electrical meaning?