In a coal fired boiler furnace temp. is high but super
heater out let temp. low what reason for this?

Answers were Sorted based on User's Feedback



In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / randhir singh yadav

Two reason
1. Scale deposit inside the boiler & superheater tube,
2. Soot deposits outer surface of boiler & superheater tube,

Is This Answer Correct ?    16 Yes 2 No

In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / ritesh patel

The specific heat of water is higher
than that of air.

Is This Answer Correct ?    5 Yes 3 No

In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / y v subba rao

Final super heater inlet steam temperature is well below than flue gas temperature of that zone(400degrees). Steam travels trough super heater coils with higher velocity(may be 25m/sec) as per the boiler design to meet the steam requirement of turbine. Hence the pretension time of steam is very less in super heater zone. More over there is always a temperature difference across the tube thickness. Due to this reasons super heater out let steam temperature is always much below than flue gas temperature in that zone. However the boiler itself will be designed in such a way.

Is This Answer Correct ?    2 Yes 0 No

In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / pradeip

because we designed boiler like that, what temperature we
require.

Is This Answer Correct ?    1 Yes 3 No

In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / lalit shukla

high cal value of coal is also the reason if we use high
amount of petcoke then furnace temp high but boiler outlet
steam temp not high

Is This Answer Correct ?    0 Yes 4 No

In a coal fired boiler furnace temp. is high but super heater out let temp. low what reason for thi..

Answer / k.p.selvakumar

1.super heated coil have any leak or puntcure.
2.continousely opened condition of attemperator valve.
3.opened all turbine draine valves in trip condition.
4.forced draught fan tamper open value high.
5.operating problem having in super heater outlet valve to main sream line.

Is This Answer Correct ?    0 Yes 5 No

Post New Answer

More Power Plant Engineering Interview Questions

operation

0 Answers  


.What is drip and drain.

2 Answers   NPTI,


1 TPH how many Megawatt ?

5 Answers   Pioneer Labs, PSAL,


What is MFT and when it is acted.

2 Answers   HPCL,


thermal power plants in steam using inlet of turbine.inlet of turbine pressure and flow is same as boiler feedpump why not use direct to turbine?

6 Answers   IBPIL, JSW,






We know primary ,secondary air so, What is the work of Tertiary air in Thermal power plant

2 Answers   NPTI,


What should be the neutral and body grounding sysytem for grid (132 KV) parallel generators (440 volts)?

1 Answers   Rahimafrooz,


what is actual CAL MODE & cal means?

2 Answers   GIPCL,


transformer shut down process.

0 Answers  


If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakage. Then it's motor current get affected or not??

1 Answers  


what is absolute separator, how it works, what are the types in it

1 Answers  


What happens if there is no HP and LP By-pass.

5 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)