What is Vk and Imag i.e Knee point voltage & Magnetising Current? How to calculate above values? How to define accuracy class 5P10?
7 53100In a 11000/440 V transformer, when any one phase of 11 KV supply fails (ie., single phasing), what happens to the secondary voltage and why?
3 20792What do you mean by validation, whats are the different steps of validation? whats are the steps followed in process validation?
2 10748How to calculate LT Network length in power distribution ? Service cable length considered or not?
2681Post New Torrent Power Interview Questions
How do I make a powerpoint presentation attractive?
What are the arguments and what do they mean in perl programming?
how do you use exceptional write in c specs?
You have been provided with a set of plates of fungi isolated from a diseased leaf, one Chytridiomycota, one Zygomycota, one Ascomycota and one Basidiomycota. The signs of infection indicate that the disease has been caused by a member of Ascomycota which does not form a sexual stage easily. What features would you look for in your isolates to indicate if the target fungus was present?
What is kurtosis?
Explain what does managed mean in the .net context?
How to write a java code in an activity? Explain with a small example.
what will be project cost for 100 kv transformer connection under oyt scheme.
What is auto login?
How one would use switch in a program?
how can you pass values to-and-fro from foreign function?
any one provide me mm & fi configration steps
If the transmitted code word is 10011000 and the received code word is 11001001. What is the error word ? Write transmitted code word , received code word and error word as polynomials.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How does the size of PMOS Pull Up transistors (for bit & bit- lines) affect SRAM's performance?