Answer Posted / dkmathur
This is the power which is utilized to produce flux /
magnatic field in a electrical equipment which is very
basic for any electrical equipment. During this process we
lose some power also. This total component of power is
called reactive power. By reducing losses we can reduce
this reactive power requirement and power factor will be
improved.
| Is This Answer Correct ? | 17 Yes | 0 No |
Post New Answer View All Answers
Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?
design of IGBT firing circuit for 11KV
How dia computation perfomed in cold rolling mills .
Draw torque - speed curve and load curve of induction motor? mark operating point ?
What is meant by a stray loss of a induction motor??? What is the equation to find it
working principles of cf lamp,incandescentlamp and f lamp?
what kelvin's law ?
What is the typical enclosure type used for Indoor switchgear / Outdoor switchgear Units? - In Onshore / offshore Units?
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
Why is the starting current high in dc motor?
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer
What are the operation carried out in thermal power station?
Why auxiliary transformers are not connected in parallel in primary stations?
In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.