what is isolation Transformer?

Answer Posted / mohammed

An isolation transformer is a transformer, often with
symmetrical windings, which is used to decouple two
circuits. An isolation transformer allows an AC signal or
power to be taken from one device and fed into another
without electrically connecting the two circuits. Isolation
transformers block transmission of DC signals from one
circuit to the other, but allow AC signals to pass. They
also block interference caused by ground loops. Isolation
transformers with electrostatic shields are used for power
supplies for sensitive equipment such as computers or
laboratory instruments.

Is This Answer Correct ?    38 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

take 100kva DTR( delta/wye ), what ll happen if we connect 11kv to LT side instead of connecting to HT side? will the DTR behave as a step up transformer or something else????

1817


What do you mean by passive circuit elements and why these are called passive?

666


What is the actual meaning of thermal power efficiency ?

1595


what is sevice settings for mccb?How can be it setted?

1585


What are the types of feedback oscillators?

823






The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.

938


how can i use REF and diffrencial relay both in 1 CT core for transformer protection?

1376


Can anyone explain me about the capacitor calculation

1715


In a 3 phase 4-wire system. For a 3.5 core cable if all loads are single phase and balanced, what will be neutral current? will it be sum of all phase currents? Or it will be zero? And if loads are unbalanced what will be neutral current?

1258


How will be the single line diagram of series trip HT breaker? how it works?

2097


If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.

994


HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT

1540


i wasted one year for the job after completed my btech what can i say about 1year time in interview

1600


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1459


what is the difference between general inverter and solor inverter clerly explain plz

1673