Is voltage & potential transformer are the same? Are they
used for same application ?
Answer Posted / r r estake
vt's are voltage transformers, based on inductive
principle,pt's are potential transformer's and covers vt &
cvt (capacitive voltage transformers).applications are same
but working is different.
| Is This Answer Correct ? | 1 Yes | 11 No |
Post New Answer View All Answers
Why strting torqe high in inducation motor?
dear sir, i completed diploma in electrical in 2005, how i can get electrical supervisor liance in mumbai
differnce between single acting and double acting solenoid valves
What are the advantages of speed control using thyristor?
I have two PLC processors. I want to communicate both processor with each other. How i can do so?
Write masons gain formula.
What is the requirement of grounding the neutral of single phase generators on load? If the neutral is not grounded, what will be the effect?
What is the difference between acs 550 & acs 850
a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5
what is the difference between the characteristics of two different phase bushing of any transformer
What does the term “voltage regulation” means?
ITI r/tv trade APPLY (J.T.O VACANCEY) ALSO INCLUD AITT ELECTRONIC,WRITEEN XAM DONE 23.03.10 BUT NO RESPONCE WHY ANATHER ID gopal_gh007@rediffmail.com
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.