Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by Active and reactive power?

Answer Posted / chetan & panks

Active Power i.e. real power is KW

Reactive Power is sin o component of Apperent power whereas
the active power is cos o component of apparent power.

cos o=kw/kva

active power=root3(VIcoso)
reactive power=root3(visino)

Is This Answer Correct ?    58 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by reverse polarity and how it can be fixed?

1197


what is V.L.F. testing of power cable? do you know the voltage ratings, like for what rating and size of cable what rating of V.L.F. testing is used?

2292


1.what is the reason for transformer and lightning arrester blast in 33kv system

3033


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1403


i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?

2003


How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.

2093


hi guys please tell me the procedure for mesuring the coil resistance of 3ph induction motor?

1839


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2585


What is time invariant system?

1104


what's producer of XLPE cable laying in undergroung

2091


what is strip power factor?

2112


how many joints are allowed in underground HT cable of 1 KM

1818


Electronic circuit

975


How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?

4416


What is use of starter and choke in tube light

1707