Answer Posted / jignesh parmar
IN MOTOR FLUX IS DIRECTLY PROPORTIONAL TO RATIO OF VOLTAGE
Vs frequency, i.e v/f it is derived from bellow formula
e= V = 4.44*flux*no. of turn*frequency
motor speed = 120*f/p
i.e speed can be ccontrolled by variying
frequency , but if only frequency increases then flux will
also increse,& flux increse beyond some level it cause
saturation also increse of flux increse loss, so to
maintain constant flux voltagge is also incresed in same
propotion to frequency as flux is directly proportion to
ratio of voltage/frequency i.e (v/f)
and that is called as variable voltage variable frequency
drive
| Is This Answer Correct ? | 79 Yes | 17 No |
Post New Answer View All Answers
Generator,motor and alternator Working principal Please explain easily
Why lose 1 phase voltage in 33kv to 415v stepdown transformer
How Can you do Maintenance of ACB of 2000Amperes
Starting current of a 10 HP induction Motor is ______ time’s full load current.
300m long and 30kw inductive loade 3phase supply how many size cable required
in conventional fan regulators how the current varies with speed?
what is formula to cal cute earth pit numbers and size of earth strip used in earthing?
DG Earth Value?
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
Under wat condition statcom operates as an inductor for the transmission line?
What are the common sources of energy?
Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.
how diside ct mf exmp.200/5 ct
If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?
what is feed back and what are feed back amplifiers?