What is auto transformer?
Answer Posted / anil kumar
An Ordinary Transformer consists of two windings called
primary winding and secondary winding.These two windings
are magnetically coupled and electrically isolated. But the
transformer in which a part of windings is common to both
primary and secondary is called Auto Transformer. These two
windings are not only magnetically coupled but also
electrically coupled.The input to the transformer is
constant but the output can be varied by varying the
tappings
| Is This Answer Correct ? | 57 Yes | 15 No |
Post New Answer View All Answers
Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?
Mention what are the types of semi-conductors?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
what is the voltages using in movie theaters??? why ??why not other??
Why a tesa lamp is glow between two phase?
Why back emf used for a dc motor? Highlight its significance.
what is the differation bewreen kwh & fundamental kwh in electronic trivector meters
which protection function should measure RMS value of current&DFT value of current?
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
what is a bus riser in power system and why it is used
how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?
what is the circutor?why we use it ?