it is clear that volts equal to the current as per ohms law.
is it appliable to the AC power or only for DC. if it is
appliacable to AC in transformers when voltage increases
the voltage decreases ????? why??????????????
Answer Posted / priyadharsini
i think its applicabe for both Ac and DC.
in transformer N1/N2=V1/V2 = I2/I1.
ie when no.of turns in primary increased voltage in primary
increased bcoz its direct propotional. and current is
inversly proportional hence the current will reduced.
i am not sure the above ans.
if correct ans known to anybody inform me too.
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?
Why different Pressure switch used in marine boiler water circulation system
what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.
What is Harmonics how it is produced and what is the method to control the same
.php|
What does the term “voltage regulation” means?
What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV
what is subtransient , transient and steady stateac components
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What are the special cables required for explosion proof wiring?
if i am in front of transmission line how to know that current direction without any equipment
what are the applications of TIG welding
Explain different types of d.c motors? Give their applications