O2F-00324: Unable to convert from the database character set
to the compiler character set
Answer Posted / guest
Cause: The name of a type, attribute, or method cannot be
converted from the client character set in effect when OTT
was invoked to the compiler character set (typically ASCII
or EBCDIC).
Action: A name is translated first from the database
character set to the client character set, and then from the
client character set to the compiler character set. The
client character set is specified in a platform-dependent
manner (On UNIX platforms, the client character set is
specified by setting the NLS_LANG environment variable). Use
a client character set that can be translated to the
compiler character set. The compiler character set itself is
one such character set. Specify synonyms in the INTYPE file
for any names of database objects that cannot be
successfully translated to the client character set.
Please add more information about this Error
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
IMP-00064: Definition of LOB was truncated by export
ORA-26027: unique index string.string partition string initially in unusable state
IMP-00063: Warning: Skipping table "string"."string" because object type "string"."string" cannot be created or has different identifier
when i ran any workflow or session, getting below error: seesion task instance[s_xxx]: Execution terminated unexpecterdly
ORA-26084: direct path context already finished
How to resolve QSM-01108 error. I have no OR conditions in my query, but do have 9 IN conditions. The error says the max limit is 2 while I have 257 number of disjuncts. However, if I remove even a single IN condition, the query is rewritten. I cannot change my query. How can I resolve this issue?
IMP-00096: Warning: Skipping table "string"."string" because type synonym "string"."string" cannot be created
ORA-26032: index string.string loading aborted after string keys
ORA-16626: failed to enable specified object
ORA-16516: The current state is invalid for the attempted operation.
IMG-02003: 2FF03 - incorrect color histogram feature specification
ORA-16627: No standby databases support the overall protection mode.
if the lengths of two wires are same and the area of cross sections is 4:7 then what will be the ratio of current passing through these wires
When i am connect database through toad,one error occured. ORA-12514: TNS:listener does not currently know of service requested in connect descriptor. plz help me thanks advance.............
IMP-00060: Warning: Skipping table "string"."string" because object type "string"."string" does not exist or has different identifier