Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is Hilic chromatography?

Answer Posted / praveen kumar_ipca

HILIC or Hydrophilic Interaction Liquid Chromatography is a high-performance liquid chromatographic (HPLC) technique for separation of polar and hydrophilic compounds. Originally the separation technique was called "Hydrophilic-Interaction Chromatography", and occasionally the expression "Aqueous Normal Phase" has also been used.

Praveen Kumar
IPCA
Sr.Excutive

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2899


how to develop the icp ms method? Application of icp ms?

846


for inorganic molecules require to do RS, Assay and disso?

774


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1752


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1873


How to fix the sample conc. in Related substances test by HPLC?

1142


why require the ph, buffer during hplc mobile phase?

919


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

2724


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1649


what is mean by 40 in the dissolution basket mesh size?

836


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

807


on the basis of bcs class how to proceed the solubility?

830


What is rs test why we are performing rs test?

1905


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2325


How will u perform degradation study in detectors other thann PDA in HPLC Methodology

2597