Please tell me 1 ton = How many Kilowatt (Electrical)
Answer Posted / abee
The are two type of kw refrigeration and electrical.
For refrigeration 1ton = 3.56 kw
For electrical 1 ton = 1.2 - 1.5 kw
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how many types control panel of a 132/33 kv substation
what is the use of commutator in dc motor if we supply ac ? commutator is used to convert ac to dc.and it is used to arrange the flux in unidirectional in case of dc supply. if we give ac as supply to dc motor what is the use of commutator?
how can we design robots
how to calculate transformer turn primary & secondary side 11kv to 420v
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points
if you are in a software company,then why do you want to come in a core company like sail, ntpc(where lots of trouble like tension but you have a good life in a it company) ?
What is electrical diversity factor in electrical installations?
If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?
what will be d.g. capacity to cater together for 14hp A.C. load & 3kw lighting load
What is the bundle conductor?
is it possible to start a motor in felid connected to a remote mcc