what are the different types of communication cables used
in automation and what are the difference in the cables
Answer Posted / hiren
Types of cables in plc
RS232 (modem), Ethernet/IP, DeviceNet (CIP), ControlNet (CIP), Modbus(RS485), Profibus(RS485), Fieldbus .
For Dcs communication cables profibus
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the use of double seated valve?
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
What is PDS and PDMS ?
Explain about safety integrated level protection? . How it was differ from other protections ?
what are procedure of sox-nox calibration
Give Detail information about plc,dcs,and scada system?
any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions?
What is standard of DCS panel design?and what is step of DCS panel design?wiring and type of connector(screw or DB connector)
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
Which language of programing is popular? how can i learn it ?
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
draw shematic diagram of c/v positioner(smart type)?