I am totally confused on IMS message segments. When I
create a message and it contains 5 segments does the entire
message have a 32k limit or does each segment have a 32k
limit? Is there a setting in the stage1 sys gen that
defines if a transaction can receive/send multi-segmented
messages?

Answer Posted / leopold holubar

Every message segment can contain up to 32k message length. As far as I know there is no limit to the number of segments, so the total message length, if you add the segments together, is virtually endless. The transaction definition determines if the input to a transaction is single or multi-segment. In contrast to that, every transaction can write single or multisegment output - there is no change in definition required for that. In the "old style" generation process in stage1 the (input message definition) parm is MODE=SINGLE or MODE=MULTI.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain the maximum number of pcbs allowed in a psb?

3357


Explain the maximum number of fields allowed per segment and what is the maximum number of fields per database?

777


Explain acbgen process?

802


What is meant by mpp mode?

769


What is mpp mode?

907


Explain psbgen process?

852


What information does a psb contain?

784


What information does a dbd contain?

788


how to create a changeman read only audit and update only audit Specifications for the Read only Audit 1) Read HFFD database unqualified. 2) Read FDRT, FDDM, FDAP segments. If FDAP-APP-STS is ‘2’ read the FDAV segment and get the FDAV segment which has FDAV-APV-OPTION as ‘X’ If FDAP-APP-STS is ‘5’ read the HFAC database. Read the ACRT segment qualified based on the key obtained from the FDAP segment from HFFD database. Conditions for writing into output file: a. App Type should be NEWR b. App Status should be 1, 2 & 5. c. Write 50 records per app status. For e.g. first 50 records for App status 1, 2 & 5 each The output file should contain the following fields from the database FDRT-COMP-CTRY-CODE X(03). FDRT-CUST-ID-NUM X(10) FDDM-DEM-SEQ-NUM X(01) FDAP-APP-SEQ X(02) FDAP-JNT-IND X(01) FDAP-APP-STS X(01) FDAV-APV-OPTION X(01) FDAV-APV-DT X(06) FDAV-APV-AMT X(07) ACRT-ACCT-NUM X(06) ACRT-SEG-BUS-TYPE X(02) ACRT-NM1-LAST X(19) ACRT-NM1-SS X(09) ACRT-NM1-1ST X(12) ACRT-NM1-INIT X(01) ACRT-NM1-SFX X(03) ACRT-NM1-TITLE X(02) PSB – DVAN2BMP In case you get a GE for any of the conditions, write to output file along with the details of the database segment which was not found. We need to complete this whole process by tomorrow. Run the audit in DLI mode. 2) Sort the output file created in step 1 on Cust ID, Dem Seq & App Seq. Specifications for the Update Audit 3) Take the output of step 2 as input for an update audit. Details are as follows: Read each record & check the app status. If app status is less than 2 then update the FDAP-NEW- MONEY-ENT to $25000.00 PSB - AUDBMPJ The job would be a BMP job. The test job would be run in IMSE region. Note - The proc (which will be called by the job) and the job should also be present in the change-man package itself. You’ll have a test job in your PDS along with overrides to execute the program in test regions. The job would be a DLI job. The test job would be run in IMSE region. It’ll have the following steps. 1) Delete-define output and error files. 2) Use a copybook for the output layout.

3435


What do you mean by hierarchical database?

790


My IMS main progam is calling Db2 subroutine ...Its giving - 923 db2 sql code..so could any one tell how to solve this issue.

3387


Can we use procopt on pcb and segment field (senseg)?

746


What is bmp mode?

3278


What is the maximum number of levels allowed in ims db?

719


What are the retrieval sequences in ims db?

1067