What are the effects of corona in switch yard.

Answer Posted / powerplant.calculations

High voltage lines during cloudy and rainy seasons create ionization of air surrounding the surface of conductor giving audible, violet, visible, intermittent discharge called corona.

Corona creates hissing sound, vibrations and power loss and radio interference
Refer for more information on basics of electrical.
https://www.powerplantandcalculations.com/2020/07/60-best-questions-answers-on-basics-of-Electricals-for-powerplant-mechanical-engineers.html

& website
www.powerplantandcalculations.com

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the trip circuit supervision in an electrical meaning?

1447


Why superheated are started before I'd and rd fan?

1700


What is difference between secondary Air & Tertiary Air and Their use.?

1483


why do you consider yourself a suitable candidate for this position

6994


LAPT working in alternator / generator

2559






can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1284


can dp type level transmitter work in under vaccum condition

1547


explain how the third harmonic content of the magnetising current affects transformer design

2777


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1240


By any way can we increase the B check hours from 300 to 500

1701


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

1484


what is the difference between compensated & normal drum level in boiler drum?

1298


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

1940


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

1828


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

520