We know primary ,secondary air so, What is the work of Tertiary air in Thermal power plant
Answer Posted / mayur mukaty
Tertiary air is used to control LOI. But Its depends upon Coal Fines %.Boiler operator on there own Experience adjust Air ratio to lower down This Parameters. But using Tertiary air instant of SA and PA. Otherwise Boiler is heavily disturb
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
By any way can we increase the B check hours from 300 to 500
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
what is the meaning of SST300 V56A in SIEMENS turbine
what is the difference between compensated & normal drum level in boiler drum?
explain how the third harmonic content of the magnetising current affects transformer design
How We Calibrate the vaccum transmitter?
what does mean by kva rating
can dp type level transmitter work in under vaccum condition
How to calculate power press toneage
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor