Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we use uracil and caffeine in hplc calibration

Answer Posted / mahesh patil

Because caffeine gives two maxima and one minima and it is more stable compound.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how many types of balance calibration test?

2293


if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

673


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

905


how decide the clining method and cleaning method validation require for this perticular products?

736


In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

3119


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1764


what are risk assement in the analytical qbd?

735


How to calibration of the uv spectroscopy and its test?

1186


if tech transfer fails whay require to do?

830


how we can identify the impurity is coming below loq at transfering site?

856


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

718


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

705


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

981


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

911


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

967