Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When electric field is parallel to the plane of incidence, the electromagnetic wave is said to be
a.Linearly polarized
b.circularly polarized
c. Elliptically polarized
d. Hyperbolically polarized

Answer Posted / shakir ullah

d. Hyperbolically polarized

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is allowed value of zero sequence impedancce of 6.6 kv nuetral earthing transformer ?what is the actual value

2104


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2270


How to select HT/MV cable size ?

2409


what is value of Jin transformer

2039


Factory acceptance test. FAT. For 132 kv transmisstion towers what is that meaning and what are the tests commonly companies perform now days.

1763


Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.

1694


what is draiv work

1838


How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.

2154


What is meant by sag?

1096


How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?

2235


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1873


who invented active elements? plz give me the complte details of active elements...

1792


Why field rheostat is kept in minimum position while armature rheostat at maximum position?

1047


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

1893


What is synchro?