What can a fresh(without experience) electrical engineer
contribute to NTPC( Or any PSU company) growth?
Answer Posted / shankar
An Experienced Guy Will Expect Something From The Company Whereas A Fresher Doesn't Have Any Experience But He is Very Adaptable to Whatever Ntpc Will Train
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
1. Design a counter which counts 0, 4, 8, 2, 6, and repeats using: 1.a using JK flip flops 1.b using T flip flops 1.c using D flip flops
What happen if 200 KVAR capacitor connected to power continuesly?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
why most of junction box vendors providing T5/T6 Temp class jb's for T3 area any special reason?
WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?
What are the classifications of oscillators?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what is PID control in VFD drives?
ACB & VCB how do work and saftes and how can maintenance in this and parts name show with picture
what is meant by IGBT how they differ from tyristor ?
What happens to a motor if it is connected in Delta connection
determine two methods to find loose connection in operational electrical system?
How is magnetic leakage reduced?
list the type of vfd? wich is sutable for heating kiln?