Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what convarts RRA in alternator ,AC to DC or DC to
AC,

Answer Posted / abhay mishra

RRA stands for Rotating Rectifier Assembly.... which converts the AC into DC which is given to the field winding of synchronous generator i.e. alternator.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?

4514


Control wiring of a dol starter for forward and backward

1636


ROC converges if poles and zeros lie inside a. Origion b. Z=1

2298


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2711


what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering

2128


What will happen if i used 11KV earth ht kit to 11 KV / 11 KV cable termination?

1476


Can we use shunt trip coil instead of trip coil with protection relay for protection?

1781


what is the correct method for the outdoor termination of 19/33 KV HT cable step by step?

2123


I have iti elec, 1st aid, and 5 yrs experience in 7.5 mw power plant. Am i eligeble for 11kv license in telangana state..when, how to apply for that.?

2358


why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

2045


What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?

1701


What do you understand by oldham's coupling ?

1125


which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor

2048


What is primary and backup protection?

1207


why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?

1981