Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When you get Moisture content by KF higher than by LOD,
what does this indicate?

Answer Posted / sandra nagarjuna

Case 1:KF will be more when samples contain lumps or big crystals
Case 2: If u r sample contain acetone or ketones ,in Kf method these two reacts with kf reagent and forms further water, so it will be more when compared to LOD

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is mean by extactable and leachable study?

1174


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1858


Why potassium dichromate is used in calibration of uv?

1988


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1981


Difference between the quantitative analysis and qualitative analysis?

1180


How to do regeneration of Metacarb Pb plus column?

2580


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

856


what is the principle involved in turbidometry and nephelometry ?

4159


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2164


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

715


From where require to take the RLD sample?

756


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6071


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1719


what are risk assement in the analytical qbd?

762


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2546