Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When you get Moisture content by KF higher than by LOD,
what does this indicate?

Answer Posted / sandra nagarjuna

Case 1:KF will be more when samples contain lumps or big crystals
Case 2: If u r sample contain acetone or ketones ,in Kf method these two reacts with kf reagent and forms further water, so it will be more when compared to LOD

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How require to perform linearity as per ANVISA? What are the acceptance criteria?

1400


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

2015


How can the GC or HPLC method is selected to determine the impurity profile in drug product?

7676


what is biorelivent dissolution media?

859


using gradient pressure in gas chromatography are not ?using gradient pressure why

3439


how you start RS method development when for new product?

776


how many types of balance calibration test?

2353


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

816


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2612


WHY given much noise PDA dector then VWD Dector

2144


Why use only methanol,used determinationof moisture content not use other solvents

1454


What is the diference between residual solvents and organic volatile matter

2109


how to get accurate result for Residue on evaporation in purified water

1697


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1827


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1260