what will happen when choke in tube light circuit was not
working???
Answer Posted / mohandas
The tube light cannot function without a choke. High voltage is required for ionisation of the argon gas in the tube light which is generated by sudden break of the circuit by the starter. The value of high voltage will depend on how fast the contacts within the starter opens. If due to aging the contacts within the starter is not opening as fast as it should then also the tube will not work as the Choke could not generate the required high voltage. Once the tube light comes on the starter will be out of the tube light circuit and if you remove the starter nothing happens to the tube light. Because the current takes shortest path of from filament to the filament through the ionised gas and the starter circuit is bypassed. The function of the choke, once the tube light comes on, will be to limit the surges in the input voltage.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
If a 3 phase induction motor is in off condition in the conveyor and rotor of the motor keeps moving with the conveyor than the resistance of windings of motor varies. why is it so ??
How to perform a DC resistance test In Alternator and their proceduces?
why and how current drawn by battery charger depends upon the altitude where it is located?
Give details on how you intend to handle a challenging position you are posted to manage unexpectedly as a company staff?
why ht motors are star connected?
what is the formula to calculate voltage drop/loss on 66KV Transmission Line?
Sir, I have applied for the of Jr.engineer(Electrical & Electronics) & ASST. LOCO PILOT at ALL RRB BOARDS. please send me all RRB Boards solved papers in the year of 2001 tO till date. i requested send me the papers to my id as soon as possible (jet_0991@yahoo.com). (This is very urgent) Thank You,
how calculate gd2 of ht motors
WHAT IS THE DIFFERENE IN ACTION OF MCB,MCCB,RCCB
What is the difference between single point and double point bonding. please kindly detail about bonding of cables.
What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?
why don't we use the generator as a motor? and what will happen?
What is the method for testing the differential protection stabilty in generator? When the time of starting What will happen if differentail protection connection wrong means?
how many types control panel of a 132/33 kv substation
how to calculate IR value of 33KV cable ??