How to calculate the size of the conductor for particular
load
Answer Posted / basavaraj
Selection of a cable is
1) Depend on load
2) Find out De-rating factors(its depend on the where we have to laid (Duct,Air,Earth)
3) Length of cable(If cable length is more we have to increase the sectional area .If shorter the length reduce the size of the cable.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM
how to calculation increase capacitor,increase power factor for three phase.
How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?
why they were using TRIAC instead relay in some controllers and what is the advantages.
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
send me any model test paper of clerical post of state bank of india.......
1.25 kg of hydrogen are burnt with stiochiometric air, the mass of air in kg required is
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.
what are the Alarm, Trip & Safety equipment (Issues) present in Power Transformers pls Mail it to ashokbabunhce@gmail.com
what do you mean by plant earthing system.
I want to know all basics of electrical engineering
What are operating procudures & Safety precautions to be observed while operating OLTC in manual mode ?
If a high resistance fault occurs,then what are the changes will happen in the system?