Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the use of capacitor in online ups?

Answer Posted / nagesh.patwari

Not All UPSs Must Have Input Harmonic Filter Capacitors
Though almost all UPS systems use capacitors in their output, one UPS topology demonstrates that reliance on capacitors in the input is not required. Delta Conversion UPS configurations are now gaining wide acceptance as a means to assure maximum compatibility and stability of engine generators without adding large input capacitor-based harmonic filters.

Instead, this design applies two bidirectional power converters so that the primary delta converter acts like an active harmonic filter, maintaining less than 5% THD current distortion from no load to full load, without the use of capacitor-based filters. The UPS maintains power factor at an ideal unity PF, never falling leading or causing voltage problems on the generator.

The double conversion UPS consists of a one-direction rectifier/battery charger driving a one-direction inverter that powers the critical load.

The two converters of the Delta Conversion UPS are bidirectional, enabling the UPS to aid in the engine-generator's stability. These two converters are controlled so that, as a load, the delta conversion is a constant unity power factor load of a sine wave form from no load to full load And, the Delta Conversion UPS achieves this ideal unity power factor and low input harmonic distortion without the need of a large input capacitor bank.

Both capacitors I/p and o/p - AC AND DC Capacitor in UPS ARE USED FOR VTG FILTRATION OR SMOOTH OUTPUT POWER

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method

1904


we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer

1796


How to calculate Air conditioning capacity for a telecom BTS shelter?

3557


Why can't we parallel Voltage transformer secondary circuits?

1707


how to commissioning the genset with amf panel?

2450


what about SAP/MRP regarding manufacturing of electric motors and all drives?

2065


What is referred to the electron in the outer orbit?

1205


What are the types of feedback oscillators?

1345


explain safety measures in alternator?

1851


A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?

2036


If not into production, how far did you follow the design and why did not you see it into production?

2225


Describe the test procedure to determine the vector group

2241


Explain the operation carried out in thermal power stations?

1077


Please give me a erda placement paper

1844


do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....

2137