what is inductive voltage transformer? what is its
application and how it differs from capacitive voltage
transformer?
Answer Posted / souvik dey
An inductive voltage transformer is a normal transformer in which the line whose voltage is to be measured is put on the primary side with desired turns ratio gives the secondary low voltage to be measured,both capacitive voltage transformer and inductive voltage transformer are same only difference is cvt is used in high voltage provisions as the use of capacitance is done to get better result,to prevent damage and for safety purpose
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
We normally make oil soak pits under Transformers. Oil from soak pit goes to collection pit. We provide granules/pebbles under transformers. My question is weather granules/ pebbles to be filled in soak pit or not? if yes upto what level?
Generator,motor and alternator Working principal Please explain easily
What is the real function of reverse power relay in generator panel while syncronising?
71ohm,111ohm,95ohm,179ohm in calculate the total ohm in series circuit
WHAT IS THE CURRENT CARRYING CAPACITY OF 2.5/3 CORE HI TUFF CABLE,WILL IT SAFLEY CARRY 8.6 AMPS OVER 120 METRES,CAN YOU ALSO ANSWER WITH FORMULA FOR WORKINGS OUT ,THANK YOU 3RDYR APPRENTICE.
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
what happen when we add mentos in cold drink?& why?
in non technical way how can u define POWER FACTOR??
what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?
Is there possible to Test Transformer for Overfluxing Capability. Or is there any firm who does Overfluxing Test on Transformer?
how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????
Why the field rheostat is adjusted such that the voltmeter reads 380V
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
how many electricity poles are there and what are the names and their sizes.
what is the difference between surge protection capacitor and surge arrestor